The product introduce
our company produces the MFTZ/BC, MFTZ/ABC series of cart type dried powder fire extinguisher which defers to the GB8109-2005 standard .It is one kind of high efficiency fire extinguisher, the fire fighting scope is big, the efficiency is high, its unique nozzle fixed and rollers make fire extinguisher operation nimbly, easy to operate.Widely applies in the industry and mining enterprise, the steamboat, the fuel depot, the gas station and so on.
The structure and composes of fire extinguisher
The fire extinguisher mainly made up of the tube body, unit, the nozzle unit, the frame unit and so on, the fire-extinguishing is carbonic acid hydrogen (ABC is for phosphoric acid ammonium salt).The actuation gas is nitrogen, the working pressure under the normal temperature is 1.5MPa.
The Main Performance and Characteristic
- The series of fire extinguisher has high fighting efficiency ,rapid and so on, the internal dried power fire-extinguishing is electric insulation, not easy to be affected with damp, easy to storage etc.
- With actuation non-toxic gas, tasteless, does not have the injury to the body after spraying.
- The fire extinguisher bottle valve is with the pressure gauge, has the function of showing its internal pressure , easily for inspection service.
- The fire extinguisher has rolling equipment to be operated easily .
The Use Scope
- Suitable in putting off the beginning fire of the flammable liquid and gas, also for the fire of charged equipment, in which MFZ/ABC also available in the fire of flammable solid.Widely applies in oil field, fuel depot, factory, store, transformer vault etc, is the necessary fire equipmentfor the fire preventing and safeguard life and property of the people
- The Temperature Scope is: -20⊥‵+55⊥﹝
Main technical parameterㄗ20⊥㊣5⊥ㄘ
|
Weight
(kg) |
Effective spraying time
(s) |
Effective spraying
distance
(m) |
Spraying lag time
ㄗsㄘ |
Sprays surplus rate
ㄗ%ㄘ |
insulation
(kv) |
鏢 鳶
撰 梗 |
A |
B |
MFTZ/ABC20 |
20㊣0.4 |
≡30 |
≡6 |
≒5 |
≒10 |
≡5 |
6 |
144 |
MFTZ/20 |
20㊣0.4 |
≡30 |
≡6 |
|
144 |
MFTZ/ABC35 |
35㊣0.7 |
≡30 |
≡6 |
6 |
183 |
MFTZ/35 |
35㊣0.7 |
≡30 |
≡6 |
|
183 |
MFTZ/ABC50 |
50㊣1.0 |
≡30 |
≡6 |
10 |
233 |
MFTZ/50 |
50㊣1.0 |
≡30 |
≡6 |
|
233 |
鞠﹜Diagram
|
1﹜frame unit
2﹜rocket unit
3﹜protector
4﹜unit
5﹜tube body unit
6﹜guard collar
|
The application method
Pushes the fire extinguisher to the fire scene, launches the spraying hose, shut the powder valve of the spraying gun; Then pulling the valve safety pin, pull open the valve, takes up the spray gun aim at the flame base to spray with the powder valve open .
The maintains
- The depositing temperature: -10⊥‵+45⊥; Does not receive the hot sun , close fire hazard or vibrated fiercely.
- The fire extinguisher should lay aside stably, deposits in the air seasoning place .
- Inspects frequently whether it is nimble and convenient.
- Inspects the safety pin and the lead sealing frequently whether it is complete, the value of pressure conform to the requirement, the spare part become less crowded, the distortion, the corrosion or the damage.
- The fire extinguisher expire should inspec the bottle valve, nozzle the tube body and so on again every two year after five years And carries on 2.6MPa the hydraulic pressure test, qualified should not carry on abandonment processing.
- The fire extinguisher service or the sufficient attire should by the intelligence specialized fire service department to repair, the user does not disassemble or repair;Refer the maintenance handbook.
|